Electric Powered Micropile Rig Zero Emission Indoor Drilling Machine
Electric Micropile Rig
,Zero Emission Drilling Rig
,Indoor Foundation Drilling Machine
Electric Powered Micropile Rig Zero Emission Indoor Drilling Machine
Basement underpinning and indoor piling are now often specified with emission and noise limits that rule out diesel plant. The MP100E runs from a 45 kW electric motor on an 80 m trailing cable, or from a 64 kWh battery pack for five hours of duty, delivering 11 kN·m of torque and 75 kN of feed while measuring 62 dB(A) at seven metres. It drills 90 to 250 mm micropiles and anchors to 35 m.
Key Features- Zero Tailpipe Emission: Electric drive removes diesel particulate and NOx from the work area, which is essential for basements, tunnels and occupied buildings.
- 62 dB(A) Noise Level: Low noise output allows night work and operation next to occupied flats and hospital wards without special dispensation.
- Cable or Battery: Run from grid power on long campaigns or from the 64 kWh pack where no supply exists, with automatic changeover between sources.
- Narrow Chassis: A 1,550 mm transport width passes through domestic side access and standard door openings in basement plant rooms.
- Energy Recovery: Regenerative lowering and feed retraction return energy to the pack, cutting consumption per drilled metre by roughly 15 percent.
- Same Tooling Interface: Chucks and rod adaptors are shared with our diesel models, so existing tooling and crew habits carry over unchanged.
| Parameter | Specification |
|---|---|
| Max Output Torque | 11 kN·m |
| Hole Diameter Range | 90 to 250 mm |
| Max Depth | 35 m |
| Drive | Electric motor 45 kW, 380 V / 50 Hz |
| Battery Option | 64 kWh lithium pack, 5 h duty |
| Feed Force / Pull Force | 75 kN / 110 kN |
| Mast Stroke | 3,300 mm |
| Transport Width | 1,550 mm |
| Operating Weight | 6,800 kg |
| Noise Level | 62 dB(A) at 7 m |
| Cable Length | 80 m trailing cable |
| Process Capability | Micropile, anchor, core drilling, jet grouting |
Specifications refer to the standard configuration of the MP100E. Values may be adjusted for site specific requirements, and a final technical proposal is issued with each order confirmation.
ApplicationsThe rig is used for underpinning of existing walls, micropiles inside basements and plant rooms, anchor installation in tunnels, and core drilling where exhaust is unacceptable. It also suits food, pharmaceutical and cold store sites where any combustion by product would contaminate the process area, and night time urban work where noise limits apply.
Because the MP100E shares its hydraulic architecture with the rest of our crawler range, contractors can standardise operating procedures, tooling interfaces and spares across a mixed fleet. Our engineers review the pile schedule, soil report and site access constraints before recommending kelly configuration, auger tooling and crowd settings, so the machine arrives already matched to the ground conditions on the project.
Packaging & Quality AssuranceThe machine ships in a 20ft container with the mast braced, battery pack isolated and cable reel crated separately. High voltage components are sealed and labelled to IEC standards, the battery carries a UN38.3 summary for transport, and an electrical commissioning checklist is supplied for the buyer's electrical contractor.
Every unit is assembled, run under load and inspected against a 42 point checklist before dispatch. The inspection covers hydraulic pressure at each circuit, winch brake holding capacity, mast verticality, torque calibration, electrical insulation and safety interlock function. Certificates for the load test, torque calibration and material traceability of the main structural weldments are issued with the shipping documents.
Why Buyers Choose This MachineElectrifying a drilling rig requires resizing the hydraulic system for constant motor speed, which is why the MP100E uses a variable displacement pump through a matched inverter. High voltage circuits are interlocked and earth fault monitored, and the battery management system limits discharge in cold conditions to protect cell life. Each unit is insulation tested and load tested before crating.
Service & Operator SupportCommissioning includes insulation resistance testing, earth continuity checks and a drilling test in each process mode. Motor bearings, inverter filters, slip rings and hydraulic filter elements are stocked. Training covers high voltage safety awareness, battery state management and isolation procedure before any work on the drive cabinet.
Spare parts are despatched from our Jiangsu warehouse with a documented lead time of 72 hours for stocked items, and we keep a recommended spare list matched to each project's pile schedule. Buyers receive operation and maintenance manuals in English, a parts catalogue with exploded drawings, and access to our technical team for remote troubleshooting through the machine's CAN-bus diagnostics port.
Ordering InformationPlease confirm the required kelly length, auger diameters, tooling package and any site specific voltage or emission requirements when placing an enquiry. We will return a formal quotation, a technical specification sheet and a preliminary shipping schedule within one working day.